  1. #Fire sprinkler system design checklist code
  2. #Fire sprinkler system design checklist plus

  • location of all exits, which will remain unblocked by any furniture.
  • location of seating, booths, stages, tables, projectors, etc.
  • Detailed (Dimensions) Site Plans and/or Floor plans showing the following examples of concern:.
  • Osceola County Fire-Rescue Special Event Permit Application Form.
  • The following items are required to be submitted for a Special Event Permit: That is why it is important to include specifications of any special effects, large displays, stages, bleachers or multi-level booths that are proposed to be used during the event.Ĭonventions, Tradeshows, Exhibitions Check List: There may be additional fees to schedule Fire Department personnel to stand fire watches that may be required for events involving open flames or special effects that may hinder the fire protection systems (Fire Alarms, Fire Sprinklers, etc.), evacuation and/or other Life Safety issues.

    #Fire sprinkler system design checklist plus

    If a production is started without a required permit the production/decorator company will be charged a double fee plus $80 with the $65 inspection fee ($365). The management will not allow you to move-in without a Special Event Permit and Stamped Approved Plans. Please use that permit number for all communication regarding that specific permit. Once we receive your Special Event Permit Application package, a permit number will be assigned that references the Special Event.

    fire sprinkler system design checklist

    ft.) Tents will require a separate Osceola County Zoning Permit

  • Scenery or other configuration changes effecting life safety features of the building.
  • Performances using special effects (i.e.
  • Assemblies (that include any of the following).
  • Please read the guideline documents at the bottom of this page before submitting your application.Įxamples of Special Events that require permits are: It is important to submit the required Special Event Permit Application Package to our office at least 21 days prior to production move-in at the venue, or additional fees may apply. Limited Term / Special Event Permit Guidelines
  • NOC (notice of commencement) / Legal description (valuation over $2,500).
  • #Fire sprinkler system design checklist code

  • Fire suppression (hood) systems shall comply with Florida Fire Prevention Code (FFPC), NFPA 1, NFPA 101, NFPA 17, and NFPA 96.
  • Required calculations shall be stamped/sealed as well.
  • Sprinkler systems permitted in which the scope of work includes 50 or more sprinkler heads shall be stamped and sealed by an engineer.
  • Sprinkler systems shall comply with Florida Fire Prevention Code (FFPC), NFPA 1, NFPA 101, NFPA 13, NFPA 20,and NFPA 24.
  • Fire alarm systems permitted with a valuation of $5,000.00 or more shall be stamped and sealed by an engineer.
  • Fire alarm systems shall comply with Florida Fire Prevention Code (FFPC), NFPA 1, NFPA 101, NFPA 70, and NFPA 72.
  • Systems design shall meet building and structural design criteria.
  • Engineered plans (if required), shall be submitted for permitting.
  • Separate plans are required for fire sprinkler, fire alarm, and fire extinguishing systems.
  • (License, addresses, phone, and fax numbers)
  • Architectural and Engineering drawings shall have certification of compliance with the Florida Building Code including raised seal, date, and signature.
  • (Florida Administrative Code) Chapter 69A.
  • Design criteria shall comply with the Florida Fire Prevention Code (FFPC).












  • Fire sprinkler system design checklist